Automatic range-switch continuity by position (1999–2000)
P: D–C and I–B; R: I–F; N: D–C and I–J; D: I–H; 2: I–E; 1: I–G. Listed pairs have continuity; other pairs do not.P: D–C and I–B; R: I–F; N: D–C and I–J; D: I–H; 2: I–E; 1: I–G. Listed pairs have continuity; other pairs do not.
Inspect stored diagnostic trouble codes first. Disconnect battery negative and remove the range switch using the factory procedure; measure the isolated switch with an ohmmeter, without external power. Use the original component contact drawing with its small locating projection above: left pairs are I above J, G above H, E above F; center contacts D then C are horizontal; far right A above B. Do not mirror this layout onto a mating harness face. The D contact is distinct from D selector range. Test all six selector positions and confirm other pairs are open. Replace if incorrect. Reinstall with new packing and lock washer, shaft in N for initial positioning, then align cut groove to neutral reference line, complete the separate nut/bolt fastening and lock-washer staking procedure, reconnect and repeat starter/reverse-lamp checks.
- NB 1999–2000 (BP-4W, 4AT) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
- Verified in: 1999 Mazda MX-5 Miata Workshop Manual
Sources (1)
View 1 source citations
Page 05–13–12–13 (PDF pp. 489–490) · Printed value & notes
Page 05–13–12–13 (PDF pp. 489–490)Printed: “Range/position Terminals Continuity P D—C I—B Yes Other No R I—F Yes Other No N D—C I—J Yes Other No D I—H Yes Other No 2 I—E Yes Other No 1 I—G Yes Other No”
Related service specs
- Automatic TCM range-input voltage reference (1999–2000)
- Automatic TCM overdrive switch and lamp voltage reference (1999–2000)
- Automatic TCM throttle voltage reference (1999–2000)
- Automatic TCM speed-signal voltage reference (1999–2000)
- Automatic TCM engine-speed input voltage reference (1999–2000)
- Automatic TCM shift and lockup solenoid output voltage reference (1999–2000)
- Automatic TCM power and ground voltage reference (1999–2000)
- Automatic TCM serial communication diagnostic limitation (1999–2000)