Showing specs for all NA & NB Miatas

Automatic transmission stall speed (1999–2000)

2,370–2,740 rpm in R, D, 2 and 1; each loaded reading within 5 seconds, with at least 1 minute idle in N between tests.2,370–2,740 rpm in R, D, 2 and 1; each loaded reading within 5 seconds, with at least 1 minute idle in N between tests.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Perform factory mechanical-test preparation first: parking brake applied, wheel chocks at front and rear of wheels; inspect engine coolant, engine oil, ATF level, ignition timing and idle speed. Start in R. Hold the brake pedal firmly with the left foot and gently depress the accelerator with the right. When engine speed stops increasing, immediately read rpm and release the accelerator. Complete the throttle/read steps within five seconds to prevent transmission damage. Select N and idle for one minute or more to cool the ATF before repeating for D, 2 and 1. High/low results require the full hydraulic and friction-element diagnostic comparison; the speed alone does not identify a failed part. No ATF temperature or idle rpm from another model year is added to this procedure.

Applies to
  • NB 1999–2000 (BP-4W, 4AT) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • Page 05–13–2–3 (PDF pp. 479–480) · Printed value & notes
    Page 05–13–2–3 (PDF pp. 479–480)
    Printed: “Engine stall speed 2,370—2,740 rpm Shift the selector to N position and let the engine idle for 1 minute or more to cool the ATF. Perform a stall test of D, 2, and 1 ranges in the same manner.”
  • Page 05–50–1 (PDF p. 516) · Printed value & notes
    Page 05–50–1 (PDF p. 516)
    Printed: “Engine stall speed (rpm) D, 2, 1 2,370—2,740 R 2,370—2,740”
    Technical table corroboration only; complete479–480factory preparation, testing sequence and safety/timing conditions remain in the current procedure. No minimum/maximum label added to time-lag values.