Factory battery load-test thresholds (1999–2000)
S46A24L(S): 105 A; record voltage after 15 seconds. Minimum voltage by approximate battery temperature: 70 °F (21 °C): 9.6 V; 60 °F (15 °C): 9.5 V; 50 °F (10 °C): 9.4 V; 40 °F (4 °C): 9.3 V; 30 °F (−1 °C): 9.1 V; 20 °F (−7 °C): 8.9 V; 10 °F (−12 °C): 8.7 V; 0 °F (−18 °C): 8.5 V.S46A24L(S): 105 A; record voltage after 15 seconds. Minimum voltage by approximate battery temperature: 21 °C {70 °F}: 9.6 V; 15 °C {60 °F}: 9.5 V; 10 °C {50 °F}: 9.4 V; 4 °C {40 °F}: 9.3 V; −1 °C {30 °F}: 9.1 V; −7 °C {20 °F}: 8.9 V; −12 °C {10 °F}: 8.7 V; −18 °C {0 °F}: 8.5 V.
For the original S46A24L(S) battery only. First measure open-circuit battery voltage. Above 12.4 V proceeds to the load test; below 12.4 V calls for quick charging for 30 minutes and rechecking. If still below 12.4 V replace the battery; above proceeds to the load test. The printed above/below branches do not assign exactly 12.4 V. Use a battery load tester at 105 A and read voltage after 15 seconds, using the approximate battery-temperature row. The factory pass question asks whether voltage is more than the specification; replace if not. Do not use this load setting for an unspecified replacement battery. For the prerequisite recharge, stop the engine and turn all accessories off, remove battery negative first and install it last. Keep flames, heat and sparks away. Follow the factory removed-battery water-pan cooling procedure: water about halfway up the case, keeping the top dry. The listed quick-charge current is 20 A and the maximum duration is 30 minutes. After recharge verify voltage remains above 12.4 V for more than one hour; replace if incorrect.
- NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
- Verified in: 1999 Mazda MX-5 Miata Workshop Manual
Sources (3)
View 3 source citations
Page 01–17–1 (PDF p. 269) · Printed value & notes
Page 01–17–1 (PDF p. 269)Printed: “Quick charge for 30 minutes and reinspect voltage. Apply test load (see test load chart) to battery using a battery load tester and record battery voltage after 15 seconds. Is voltage more than specification? Test load chart Battery S46A24L(S) Load (A) 105 Approximate battery temp. Minimum voltage (V) 21 °C {70 °F} 9.6 15 °C {60 °F} 9.5 10 °C {50 °F} 9.4 4 °C {40 °F} 9.3 −1 °C {30 °F} 9.1 −7 °C {20 °F} 8.9 −12 °C {10 °F} 8.7 −18 °C {0 °F} 8.5”Page 01–17–2 (PDF p. 270) · Printed value & notes
Page 01–17–2 (PDF p. 270)Printed: “Do not quick charge for over 30 minutes. It will damage the battery. After the battery has been recharged, measure the battery positive voltage and verify that the battery keeps specified voltage for more than 1 hour. Specification Above 12.4 V”Page 01–50–2 (PDF p.313) · Printed value & notes
Page 01–50–2 (PDF p.313)Printed: “Test load chart (A) Battery type S46A24L (S) 105”Original1999 technical table checked against the complete current record and its separately cited procedure; existing value and applicability retained.
Related service specs
- Generator output-current reference test (1999–2000)
- Knock-sensor resistance (1999–2000)
- Ignition coil secondary-winding resistance (1999–2000)
- High-tension ignition lead resistance (1999–2000)
- Starter on-vehicle diagnostic voltage (1999–2000)
- Starter no-load voltage and current test (1999–2000)
- Starter armature runout limit (1999–2000)
- Starter commutator diameter (1999–2000)