Showing specs for all NA & NB Miatas

Generator output-current reference test (1999–2000)

Reference terminal B current: approximately 0–60 A at 1,000 rpm and approximately 0–68 A at 2,000 rpm; must not be 0 A. Measuring conditions: room temperature 68 °F (20 °C), 13.5 V, engine hot.Reference terminal B current: approximately 0–60 A at 1,000 rpm and approximately 0–68 A at 2,000 rpm; must not be 0 A. Measuring conditions: room temperature 20°C (68°F), 13.5 V, engine hot.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Verify the battery is fully charged and drive-belt deflection/tension is correct. Disconnect the negative battery cable before connecting a circuit tester capable of reading 120 A or more in series between generator terminal B and its wiring harness, then reconnect the negative cable. Turn all electrical loads off, start the engine and increase engine speed to 2,000–2,500 rpm for the load-response check. Turn on the headlights, blower motor and rear window defroster and verify that terminal B current increases. If it does not increase, disassemble and inspect the generator as directed. The separate reference table gives readings at 1,000 and 2,000 rpm under its stated measuring conditions; these are not rated-output guarantees or minimum loaded outputs. Current required varies with electrical loads applied. Generator terminal B can spark if it touches the vehicle body while battery cables are connected; disconnect the battery before connecting or removing test wiring.

Applies to
  • NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • Page 01–17–3–4 (PDF pp. 271–272) · Printed value & notes
    Page 01–17–3–4 (PDF pp. 271–272)
    Printed: “Connect a circuit tester, capable of reading 120 A or over, between generator terminal B and the wiring harness. Standard current (Reference) Measuring conditions Room temperature: 20 °C {68 °F} Voltage: 13.5 V Engine hot 1,000 Approx. 0—60 (must not be 0) 2,000 Approx. 0—68 (must not be 0)”
  • Page 01–50–2 (PDF p. 313) · Printed value & notes
    Page 01–50–2 (PDF p. 313)
    Printed: “Generated current (Reference) (A) Engine speed (rpm) 1000 Terminal B current Approx. 0—60 (must not be 0) 2000 Terminal B current Approx. 0—68 (must not be 0)”