Showing specs for all NA & NB Miatas

Starter armature runout limit (1999–2000)

0.001 in (0.03 mm) maximum.0.03 mm {0.001 in} maximum.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

With the starter removed and disassembled using the factory procedure, place the armature shaft on V-blocks. Measure runout using a dial indicator on the commutator cylindrical contact surface while rotating the armature. If outside specification, repair using a lathe or replace the armature. This is commutator runout in the illustrated shaft-support setup, not pinion end clearance or shaft endplay.

Applies to
  • NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (1)

View 1 source citations
  • Page 01–19–3 (PDF p. 280) · Printed value & notes
    Page 01–19–3 (PDF p. 280)
    Printed: “Place the armature on V-blocks, and measure the runout by using a dial indicator. Runout 0.03 mm {0.001 in} max. If not within the specification, repair by using a lathe or replace the armature.”