Showing specs for all NA & NB Miatas

Starter on-vehicle diagnostic voltage (1999–2000)

Above 8 V at starter terminals S and B with ignition in START, when directed after abnormal cranking.Above 8 V at starter terminals S and B with ignition in START, when directed after abnormal cranking.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Verify the battery is fully charged. Crank and check that the starter turns smoothly without noise. If incorrect, measure voltage at the starter S and B terminals during START. If voltage is within specification, remove the starter using the factory battery-disconnection procedure and inspect the magnetic switch and starter. If voltage is incorrect, inspect wiring, ignition switch and the applicable MT starter-interlock or AT range switch. This is a conditional cranking diagnostic, not an idle charging-voltage target.

Applies to
  • NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (1)

View 1 source citations
  • Page 01–19–1–2 (PDF pp. 278–279) · Printed value & notes
    Page 01–19–1–2 (PDF pp. 278–279)
    Printed: “If not as specified, measure the voltage at terminals S and B when the ignition switch is in the START position. Specification Above 8 V”