Fuel pump isolated continuity (2003)
Continuity between pump terminals B and D.Continuity between pump terminals B and D.
Perform only when directed by the factory fuel-pump inspection. Disconnect the negative battery cable, remove the service-hole cover and unplug the fuel-pump connector. Check continuity on the pump side between B and D. The part-side connector is viewed from its terminal side: D upper left, C upper right, B lower left, A lower right as drawn, with the key projections on the right. If there is no continuity, replace the pump body; if continuity is correct, continue the separate harness open/short diagnosis. No numerical winding-resistance criterion is given.
- NB 2003 (BP-Z3)
- Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)
Sources (1)
View 1 source citations
- 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Fuel Pump Inspection — continuity (PDF p.712) · Printed value & notes
Page Fuel Pump Inspection — continuity (PDF p.712)Printed: “Perform the following test only when directed. Disconnect the negative battery cable. Remove the service hole cover. Disconnect the FP connector. Inspect for continuity between FP connector terminals B and D. If there is no continuity, replace the FP body. PART SIDE CONNECTOR (VIEW FROM TERMINAL SIDE)”
Related service specs
- VTCS solenoid valve resistance screening (2001–2004)
- Intake manifold vacuum at idle (2001–2003)
- VTCS check/delay valve directional airflow (2003)
- Intake manifold gasket orientation (2003)
- Dynamic chamber gasket orientation (2003)
- Dynamic chamber bracket tightening order (2003)
- Fuel drawing pump hose preparation (2003)