Showing specs for all NA & NB Miatas

Intake manifold vacuum at idle (2001–2003)

More than 60 kPa {450 mmHg, 18 inHg} vacuum at idle.More than 60 kPa {450 mmHg, 18 inHg} vacuum at idle.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Verify the air-intake hoses are installed properly. Start the engine and run it at idle, then measure intake-manifold vacuum with a vacuum gauge. This is a vacuum reading, not an absolute manifold-pressure PID. If below specification, inspect for intake air leakage at the throttle-body, intake-manifold and PCV-valve installation points and fuel-injector insulators; also inspect accelerator-cable free play and engine compression as directed by the factory procedure. The source does not assign a test temperature or a numerical idle speed here.

Applies to
  • NB 2001–2003 (BP-Z3) — 2002 applicability is supported by matching text in publication 1719-1U-01G; 2001 follows the owner-approved early-NB2 carry-over policy and is not an independently verified year.
  • Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)

Sources (2)

View 2 source citations
  • Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
    Page PDF p. 252 · Printed value & notes
    Part no. 1719-1U-01G
    Page PDF p. 252
    Printed: “Verify air intake hoses are installed properly. Start the engine and run at idle. Measure the manifold vacuum using a vacuum gauge. Specification More than 60 kPa {450 mmHg, 18 inHg}”
  • 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Engine Control System Operation Inspection — Intake Manifold Vacuum Inspection (PDF p.548) · Printed value & notes
    Page Engine Control System Operation Inspection — Intake Manifold Vacuum Inspection (PDF p.548)
    Printed: “Verify air intake hoses are installed properly. Start the engine and run at idle. Measure the manifold vacuum using a vacuum gauge. Specification More than 60 kPa {450 mmHg, 18 inHg}”