PCM EGR step-position reference (1999–2000)
SEGRP: ignition ON, 0 step; idle, 0 step; cranking, 0—60 steps.SEGRP: ignition ON, 0 step; idle, 0 step; cranking, 0—60 steps.
Connect the NGS tester to DLC-2, turn ignition ON, select PID/DATA MONITOR AND RECORD and press TRIGGER, select the named parameter and press START. These are reported PCM references, not permission to apply a signal to a connector or adjust the component. Read the SEGRP position parameter in steps. These are the stated key-on, idle and cranking references, not a user command to sweep the EGR motor or a valve opening in degrees. If incorrect, inspect associated ECT V and TP V inputs and follow the factory EGR diagnosis. The separate simulation/control check uses its own operating and observation procedure.
- NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
- Verified in: 1999 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page 01–40–4 (PDF p. 293) · Printed value & notes
Page 01–40–4 (PDF p. 293)Printed: “Connect the NGS tester to the DLC-2. Turn the ignition switch on. Select the appropriate PID on the NGS display and press START. Measure the PID value.”Page 01–40–7 (PDF p. 296) · Printed value & notes
Page 01–40–7 (PDF p. 296)Printed: “SEGRP (EGR valve (stepping motor) position) step Ignition switch ON: 0 step Idle: 0 step Cranking: 0—60 steps”
Related service specs
- Generator output-current reference test (1999–2000)
- Knock-sensor resistance (1999–2000)
- Factory battery load-test thresholds (1999–2000)
- Ignition coil secondary-winding resistance (1999–2000)
- High-tension ignition lead resistance (1999–2000)
- Starter on-vehicle diagnostic voltage (1999–2000)
- Starter no-load voltage and current test (1999–2000)
- Starter armature runout limit (1999–2000)