PCM generator field and output-voltage scan references (1999–2000)

ALTF: ignition ON, 0%; idle, 0—100%; with generator operating, duty rises when electrical loads turn ON. ALT T V: ignition ON, 0 V; idle, B+ +1 V.ALTF: ignition ON, 0%; idle, 0—100%; with generator operating, duty rises when electrical loads turn ON. ALT T V: ignition ON, 0 V; idle, B+ +1 V.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Connect NGS tester to DLC-2, turn ignition ON, select PID/DATA MONITOR AND RECORD and press TRIGGER, select the named PID and press START. Observe each printed condition separately. These are PCM scan-tool reference readings, not direct connector voltages or commands to energize a component. If incorrect, follow the factory action column and associated inspection. Read the generator field duty ALTF and the separately reported output voltage ALT T V. B+ is battery positive voltage; retain the printed relative idle reference B+ +1 V rather than replacing it with a fixed charging range. If incorrect, check IAT, IAT V, RPM, B+, B+2 and the companion generator PID and perform the factory generator inspection. The duty reference is not a minimum generator output-current specification.

Applies to
  • NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (1)

View 1 source citations
  • Page 01–40–4 (PDF p.293) · Printed value & notes
    Page 01–40–4 (PDF p.293)
    Printed: “ALTF (Generator field coil control duty value) Ignition switch ON: 0% Idle: 0—100% Generator operating → E/L ON: Duty value rise ALT T V (Generator output voltage) Ignition switch ON: 0 V Idle: B+ +1 V”