Showing specs for all NA & NB Miatas

PCM idle-air valve pulse-width reference (1999–2000)

IACV: ignition ON, 1.0 ms; idle, 0.3—1.0 ms; TEN shorted, 0.3—0.7 ms.IACV: ignition ON, 1.0 ms; idle, 0.3—1.0 ms; TEN shorted, 0.3—0.7 ms.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Connect the NGS tester to DLC-2, turn ignition ON, select PID/DATA MONITOR AND RECORD and press TRIGGER, select the named parameter and press START. These are reported PCM references, not permission to apply a signal to a connector or adjust the component. Read IACV in milliseconds. The TEN-shorted condition uses the factory TEN-to-body-ground tune-up preparation; it is separate from ordinary idle. Do not confuse this pulse-width parameter with the percent duty commanded during the separate simulation test or with valve winding resistance. For output-device diagnosis, the factory requires the simulation test after PID monitoring and associated input checks; do not command an arbitrary setting from these reference values.

Applies to
  • NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • Page 01–40–4 (PDF p. 293) · Printed value & notes
    Page 01–40–4 (PDF p. 293)
    Printed: “Connect the NGS tester to the DLC-2. Turn the ignition switch on. Select the appropriate PID on the NGS display and press START. Measure the PID value.”
  • Page 01–40–6 (PDF p. 295) · Printed value & notes
    Page 01–40–6 (PDF p. 295)
    Printed: “IACV (Idle air control valve) ms Ignition switch ON: 1.0 ms. Idle: 0.3—1.0 ms. Short terminal TEN: 0.3—0.7 ms.”