PCM idle-air valve pulse-width reference (1999–2000)
IACV: ignition ON, 1.0 ms; idle, 0.3—1.0 ms; TEN shorted, 0.3—0.7 ms.IACV: ignition ON, 1.0 ms; idle, 0.3—1.0 ms; TEN shorted, 0.3—0.7 ms.
Connect the NGS tester to DLC-2, turn ignition ON, select PID/DATA MONITOR AND RECORD and press TRIGGER, select the named parameter and press START. These are reported PCM references, not permission to apply a signal to a connector or adjust the component. Read IACV in milliseconds. The TEN-shorted condition uses the factory TEN-to-body-ground tune-up preparation; it is separate from ordinary idle. Do not confuse this pulse-width parameter with the percent duty commanded during the separate simulation test or with valve winding resistance. For output-device diagnosis, the factory requires the simulation test after PID monitoring and associated input checks; do not command an arbitrary setting from these reference values.
- NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
- Verified in: 1999 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page 01–40–4 (PDF p. 293) · Printed value & notes
Page 01–40–4 (PDF p. 293)Printed: “Connect the NGS tester to the DLC-2. Turn the ignition switch on. Select the appropriate PID on the NGS display and press START. Measure the PID value.”Page 01–40–6 (PDF p. 295) · Printed value & notes
Page 01–40–6 (PDF p. 295)Printed: “IACV (Idle air control valve) ms Ignition switch ON: 1.0 ms. Idle: 0.3—1.0 ms. Short terminal TEN: 0.3—0.7 ms.”
Related service specs
- Generator output-current reference test (1999–2000)
- Knock-sensor resistance (1999–2000)
- Factory battery load-test thresholds (1999–2000)
- Ignition coil secondary-winding resistance (1999–2000)
- High-tension ignition lead resistance (1999–2000)
- Starter on-vehicle diagnostic voltage (1999–2000)
- Starter no-load voltage and current test (1999–2000)
- Starter armature runout limit (1999–2000)